Dongguan Lixian Instrument Scientific Co., Ltd.
Products
Contact Us
  • Contact Person : Ms. Zhong Fiona
  • Company Name : Dongguan Lixian Instrument Scientific Co., Ltd.
  • Tel : 86-769-89820766
  • Fax : 86-769-22677452
  • Address : Guangdong,Dongguan City,No.88 Shengfeng Road,Hengjiao Village,Xinhe Community,Wanjiang District
  • Country/Region : China
  • Zip : 523047

Programmable Salt Spray Testing Chamber HZ-2001A

Programmable Salt Spray Testing Chamber HZ-2001A
Product Detailed
Related Categories:Testing Equipment
1.Programmable salt spray testing chamber 2.salt fog chamber 3.Warranty 3 years 4.ASTM/ISO standards 5.easy to operate

Programmable salt spray testing chamber

 

Equipment summary:

Programmable salt spray testing chamber used to test the corrosive resistance of products whose the surface was treated with paint, electroplating, inorganic and organic film, anode handling, anti-rust oil,etc.

corresponding standard of the programmable salt spray testing chamber:

1.GB/T 2423.17-1993 salt spray test

2.GB/T 2423.18-2000 salt spray test

3.GB/T 10125-1997 salt spray test

4.ASTM.B117-97 salt

5.JIS H8502 salt spray test

6.IEC68-2-11 salt spray test

7.IEC68-2-52 1996 salt spray test

8.GB.10587-89  salt spray test

9.CNS.4158  salt spray test

10.CNS.4159 CASS  Accelerated acetic acid copper salt spray test

11..GB/T 12967.3-91 CASS  Accelerated acetic acid copper salt spray test

 

Technical parameters of the programmable salt spray testing chamber: 

Model

HZ-2001C

HZ-2001B

HZ-2001A

Inside box size(cm)

60x45x40

90x60x50

120x80x50

Outside box size(cm)

107x60x118

141x88x128

190x110x140

Testing room temperature

Salt test (NSS ACSS)35±1 degree / Corrosion Test (CASS)50±1 degree

Pressure barrel temperature

Salt test (NSS ACSS)47±1 degree / Corrosion Test (CASS)63±1 degree

Brine temperature

35±1 degree or  50±1 degree

Testing room Capacity

108L

270L

480L

Brine tank capacity

15L

25L

40L

Salt concentration

The concentration of sodium chloride 5% or the 5% concentration of sodium chloride add 0.26g per liter of copper chloride (CuCl2 2H2O)

Air pressure

1.00±0.01kgf/cm2

Spray volume

1.0~2.0ml/80cm2/h (working at least 16 hours, and then take the average)

Testing room relative humidity

85% above

PH

6.5~7.2 3.0~3.2

Spray form

Programmable spray (Including continuous and intermittent spray)

power

AC220V1Φ10A

AC220V1Φ15A

AC220V1Φ20A

                                HZ-2001C                                          HZ-2001B

Programmable Salt Spray Testing Chamber HZ-2001A



Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.